Operator Training |
- System Operation
- System overview
- Startup/Shutdown
- Control points
- Loading/Unloading methods
- Initializing and testing
- Debugging
- Functionality
- Diagnostics
- Safety
- Parts and Maintenance
- Fundamental operator maintenance
- Parts replacements
|
|
Control Systems |
- Operator Level Training Indramat , 950m, Siemens 810D (not 840)
- Sequence of Operation Overview
- Step Through the Main Menu
- Teaching Points
- Manual, Jog, and Safety Modes
- Gantry Components and Functions
- I/O Diagnostic
- I/O Mapper (Indramat)
- Downloading and Uploading Points
- Storing Points
- Downloading and Uploading Parameters
- Program Overview
|
|
Preventive Maintenance |
- Lube Systems
- Inspect filters
- Inspect lines & fittings
- Check operation
- Verify lube / pump operation
- Air Systems
- Inspect filters
- Check pressure / adjust regulator
- Inspect system for leaks
- Drain Water Trap
- Electrical Systems
- Clean electrical cabinet
- Check voltages
- Inspect electrical ground connections
- Replace or clean fan filter
- Check limit switches / safety locks
- Mechanical Systems
- Check machine level
- Change gearbox oil
- Inspect drive units
- Inspects guides and bearings
- Clean / lubricate chains
- Inspect lines hoses and cables
- Clean chips and drip pans
|
|
Machine Debug & Runoff |
- Customized to each application
- Testing and acceptance requirements and procedures
- Equipment debugging
- Documentation
|
|